Based on legacy TIIOCTI notes on moisture damage in bag shipments, reorganised around two loading plans buyers actually choose between.
Two loading instructions landed on the same desk in the same week. One came from a buyer who had shipped canvas totes for six years and specified desiccant strips across the roof line, four kilos per twenty cubic metres. The other came from a first-time importer who had been told to leave a 50 mm air gap at the top and trust the movement of air. Both documents described a dry container, both were written by people who had lost money to wet cartons, and neither buyer could explain what the other plan was for.
The two plans are not rivals in every respect. They answer different failure modes, and a shipment can need one, the other, or both. What follows sets the two loading plans against each other on the four points that decide a claim: container rain, cargo sweat, contact water and carton strength.
Two Loading Plans on the Same Container Floor

The desiccant plan treats the container as a sealed box that must be dried from the inside. Strips are hung along the roof line, sized at 4 kg of capacity per 20 cubic metres of cargo, and they pull vapour out of the air before it can condense on steel. The crew is told to dry the floor, check the hatch seal and photograph the empty container before the first pallet goes in.
The gap plan treats the container as a space that must keep moving air. The top carton sits 50 mm below the roof, and that channel lets vapour travel instead of settling on one surface. Nothing is hung, nothing is consumed, and the cost sits in how the pallets are stacked rather than in a purchase order.
A stow that blocks either plan defeats it. Cargo packed hard to the roof stops air from moving, and a desiccant strip then dries only the pocket of air around itself rather than the whole box. Whichever plan a buyer picks, the loading instruction has to say what happens at the top of the stack.
Container Rain: What the Roof Line Desiccant Plan Actually Stops

Container rain forms on the inside of a steel roof when the outside temperature drops. The roof cools faster than the air beneath it, vapour condenses on the metal, and the drops fall onto the top layer of cargo. On a long voyage this can repeat for days, and the top tier takes the damage while the pallets below stay dry.
A 20 C swing between the loading port and cold water can drop about 30 g of free water per square metre inside a 40 ft container. That figure is the reason the desiccant plan exists. Strips hung at the roof line meet the vapour before it reaches the steel, and the roof stays dry enough that nothing drips.
The gap plan does not stop condensation from forming. It changes where the water lands. Air moving through the 50 mm channel carries vapour away from the roof surface and spreads it through a larger volume, so the roof stays closer to the air temperature and drips less. On a short route with a mild temperature drop, that can be enough. On a route that crosses the tropics and then enters cold water, the gap alone leaves the roof line exposed.
Cargo Sweat: What the Air Gap Plan Actually Stops
Cargo sweat comes from the goods. Pallets leave a humid factory holding moisture in the fibre, the carton board and the pallet timber, and when the container moves into a cold hold that moisture leaves the cargo and condenses. The water appears on the product rather than on the roof, which is why a buyer who only inspects the top layer can miss it.
The gap plan works on this source better than the desiccant plan in one respect. Moving air carries moisture away from the carton faces and spreads it, so the goods dry toward the air instead of holding a wet layer against the board. A 50 mm channel at the top gives that air somewhere to go.
Desiccant also helps with cargo sweat, because it lowers the overall vapour pressure in the box. The limit is capacity. A strip sized for 20 cubic metres of cargo will be exhausted faster by wet pallets than by a dry load, and once it is spent it stops working. The gap keeps functioning as long as the stow leaves it open.
Contact Water and Carton Strength, Where Neither Plan Is Enough

Contact water enters from below or from the side. A wet pallet base, a damp carton liner or a leaking hatch seal feeds water upward into the load, and neither a roof line strip nor a top air gap touches it. This is the source that hides longest, because the bags inside a carton can show a stain only after the board has been wet for days.
Corrugated board at 14 percent moisture content loses about 40 percent of its stacking strength. A wet carton fails long before the bags inside show anything, and the failure shows up as crushed corners and a collapsed stack rather than as mildew. By the time a buyer sees the stain, the carton has already told the story.
The controls for contact water belong in the loading instruction, not in either plan. Dry the container floor and check the hatch seal before loading, then record a photo of the empty floor. Load pallets with a moisture content under 18 percent and reject any with dark base boards. Those steps cost almost nothing and must be ordered before the container arrives.
Cotton, PP Woven and Coated Canvas Under Each Plan

Fibre choice sets how much water the bag itself will carry, and that changes the balance between the two plans. Cotton takes moisture into the fibre and holds it. Cotton canvas reaches about 8.5 percent moisture regain at 65 percent relative humidity, and a cotton tote needs a full day at 30 C to dry after a wipe down.
PP woven fabric keeps water on the surface and absorbs about 0.05 percent of its own weight. A PP bag dry within hours of a wipe, which means a PP load releases far less vapour into the container and gives both plans an easier job. A coated canvas sits between the two until the coating cracks at a fold, and then the exposed fibre behaves like cotton at that point.
A dusty or greasy bag travels worse than a clean one, because soil holds water against the yarn. Under the gap plan that moisture sits in the load with nothing pulling it out. Under the desiccant plan the strips work harder and run out sooner. Either way, a clean bag at packing is part of the moisture control.
Who Should Choose Desiccant Strips and Who Should Choose the Gap
The desiccant plan suits a load that will cross a large temperature swing, especially a route that ends in cold water after a humid loading port. It also suits cotton and coated canvas, which carry more moisture into the box and release it slowly. A buyer shipping a mixed load with a high proportion of cotton totes has more reason to hang strips than a buyer shipping PP.
The gap plan suits a load where the stow can be controlled and the route is shorter or milder. It costs nothing to specify and nothing to consume, and it works on cargo sweat without a capacity limit. It fails when the container is packed to the roof, when the route includes a hard temperature drop, or when the crew treats the top layer as spare space.
Most shipments that carry a real moisture risk use both. The strips handle the roof line and the vapour load, the gap keeps the air moving so the strips are not working in a sealed pocket, and the floor and pallet checks handle the source neither plan reaches. The choice is less about picking one and more about knowing which one is doing the work on a given order.
A Decision Table for the Loading Instruction
| Decision point | Desiccant strips | 50 mm air gap | Use both when |
|---|---|---|---|
| Container rain risk | Meets vapour before it reaches the roof | Spreads vapour, does not stop roof condensation | Route crosses tropics then cold water |
| Cargo sweat | Lowers vapour pressure, limited by capacity | Carries moisture away from carton faces | Cotton or coated canvas in a humid load |
| Contact water | No effect | No effect | Always pair with floor, seal and pallet checks |
| Carton strength | Protects top tier from drips | Protects stack only if the stow stays open | Board moisture above 14 percent is a reject |
| Fibre type | Best for cotton and coated canvas | Best for PP woven | Mixed loads with cotton and PP together |
| Stow discipline | Needs open air around the strips | Needs the top channel kept clear | Crew can follow a written loading instruction |
The table is not a menu. Each row is a line in the loading instruction, and the crew needs the line that applies to the order in front of them. A buyer who sends only the table and no instruction has sent a document, not a plan.
What to Record Before the Container Seals

Cartons are counted and photographed before the container seals, and that record is what makes either plan defensible later. Photograph the empty floor after drying, note the hatch seal check, and keep the image with the loading date. If desiccant strips go in, record the batch number and where the strips were hung.
At arrival, open the container within 4 hours and inspect the top layer first, because that is where container rain shows. Check 5 pieces per 500 for smell, mottling and yarn strength, and put a moisture meter on the cartons at the same time. A bag with surface mildew on under 5 percent of its face recovers with a wipe using a 0.5 percent sodium hypochlorite solution followed by drying at 30 C for 24 hours. A bag with yarn rot does not recover, and a claim is stronger when the loading photos, the desiccant batch number and the arrival moisture readings travel together in one file.
FAQ
How much desiccant does a 40 ft container of bags need?
Plan on 4 kg of desiccant capacity per 20 cubic metres of cargo, placed as strips along the roof line. The figure scales with cargo volume, not container size, so a light load of bulky totes needs the same calculation as a dense one.
Does a 50 mm gap at the top really stop container rain?
It reduces roof condensation by keeping air moving, but it does not stop condensation from forming on cold steel. On a route with a hard temperature drop, the gap alone leaves the top layer exposed and needs desiccant alongside it.
How soon should a container be opened after arrival?
Within 4 hours. The top layer shows container rain first, and a moisture meter reading taken at that point is worth more in a claim than a reading taken after the load has sat in a warehouse for a week.
Can surface mildew on a bag be cleaned off?
Surface mildew on under 5 percent of the face clears with a 0.5 percent hypochlorite wipe and drying at 30 C for 24 hours. Yarn rot does not recover, and a bag with rot supports a claim rather than a rework.